Please use this identifier to cite or link to this item: http://13.232.72.61:8080/jspui/handle/123456789/6643
Title: Method development and validation for simultaneous estimation of Diacerein and Glucosamine in marketed product
Authors: Akbar G., Momin Mohammad
Narajji, Chandrashekhar
Keywords: Method development and validation for simultaneous estimation of Diacerein and Glucosamine in marketed product
Issue Date: May-2011
Publisher: Acharya & BM Reddy College of Pharmacy (ABMRCP)
Citation: Akbar G,Momin Mohammad;.Narajji, Chandrashekhar; Method development and validation for simultaneous estimation of Diacerein and Glucosamine in marketed product;http://lrc.acharyainstitutes.in:8080/jspui/handle/123456789/821
Abstract: A RP-HPLC method was developed for simultaneous estimation of Diacerein and Glucosamine tablet formulation using Phenomenex Luna C18 column (250 × 4.6 mm i.d., 5 μm particle size) and a mobile phase of acetonitrile: o-phosphoric acid solution (0.001 % v/v) in HPLC water pH 4 (40:60 v/v), at flow rate 1.0 ml/min with UV detection at 220 nm. The retention time (tR) of Diacerein and Glucosamine found to be 15.449 and 1.996 min respectively. The proposed method was validated for linearity, accuracy, precision, LOD, LOQ. Linearity, accuracy and precision were found to be well within the acceptance limit. Linearity over the concentration range found to be 5-25 μg/ml for Diacerein and 100-500 μg/ml for Glucosamine with regression coefficient (r2) 0.9994 and 0.9992 respectively. Limit of detection found to be 0.52 and 0.16 μg/ml whereas limit of quantition found to be 1.6 and 0.509 μg/ml for Diacerein and Glucosamine respectively. Precision calculated by % RSD for Diacerein 0.15-1.5 and Glucosamine 0.02-0.8 %. The accuracy of the proposed method was determined by recovery studies and found to be 99.25-99.98 and 99.47-100.51 % Diacerein and Glucosamine respectively. A UV-visible spectrophotometric method was developed for simultaneous estimation of Diacerein and Glucosamine in marketed tablet formulation using HPLC methanol as solvent. The proposed method was developed by simultaneous equation method and absorbencies were measured at wavelength 257 nm for Diacerein and 202 nm for Glucosamine. Linearity over the concentration range found to be 2-10 and 25-100 μg/ml respectively with regression coefficient (r2) 0.9991 and 0.9993 respectively. LOD found to be 0.025 and 1.031μg/ml respectively whereas LOQ found to be 0.076 and 3.125 Abstract Department of Quality Assurance, ABMRCP, Bangalore-90 μg/ml for Diacerein and Glucosamine respectively. Precision calculated by % RSD for Diacerein 0.21-1.2 and Glucosamine 0.8-1.23 %. The accuracy of the proposed method was determined by recovery studies and found to be 102.66-110.19 and 102.16-102.89 % for Diacerein and Glucosamine respectively. The proposed methods are simple, accurate, precise and suitable for analysis of marketed tablet formulation containing Diacerein and Glucosamine.
Description: Dissertation
URI: http://13.232.72.61:8080/jspui/handle/123456789/6643
Appears in Collections:Dissertations

Files in This Item:
File Description SizeFormat 
10. Abstract.pdfAbstract203.48 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.